Certification Body Name:
IMQ - ISTITUTO ITALIANO DEL MARCHIO DI QUALITA' S.p.A.

Back to members

 

CB Acronym: IMQ ID #: 03
Contact person: Dr. Mauro Casari
Address 1: Via Quintiliano 43
City: MILANO Postal code: I - 20138
State / Province: IT Country: Italy
Address 2:
Email address: mauro.casari@imq.it Url: http://www.imq.it
Business phone: +39 02 5073 707 Fax:
Mobile phone:  
Deadline for the next Re-assessment: 2024-11-03
Comments:

Aditionnal contacts informations

Mr. Matteo Raismondi

Email address: matteo.raimondi@imq.it
Business phone: +39 02 5073 707 Fax:
Mobile phone:
 

 

 

ENEC
CB IMQ - Product Category
BATT
CAP
CONT
HOR
HOUS
INST
ITAV
LITE
MISC
POW
PROT
SAFE
TOOL
Laboratory Name Acronyme Country City
Guangdong Testing Institute of Product Quality Supervision GQI China Guangzhou
Istituto Italiano del Marchio di Qualita S.p.A. IMQ Italy Milano
IMQ IBÉRICA, S.L.U. IMQ Ibérica Spain Picanya
MTL type MTL Laboratory Name MTL Address MTL Country Standards Covered Registration date Latest Revision date Report Ref.
E-CTF 2 3F FILIPPI S.p.A. (PROVE E COLLAUDI) Via del Savena, 28 IT-40065 Pianoro Bologna (BO) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.4.5, 4.11.6, 4.13.6, 4.14.1, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 8.2.7, 9.2.8, 9.2.9, 9.3.1, 12.5.1e) Annex C Fig. C3, 12.7.2, 13.2.1, 13.3.1, 13.3.2, 13.4.1); EN 60598-2-1:1989; EN 60598-2-2:2012; EN 60598-2-4:2018; EN 60598-2-22:2014 (All clauses except 22.17.1 Annex C, 22.19 [Type of operation: centrally supplied emergency luminaires only]) [EMC] EN 55015:2013 + A1:2015 (All clauses except: - Insertion loss measurement - Radiated disturbance measurements in semi-anechoic chamber (frequency range 30 MHz to 300 MHz covered by independent method)); EN 61000-3-2:2014; EN 61000-3-3:2013 2007-03-06 2021-04-08 IMQ-078/CTF2-G
E-CTF 2 A.A.G. STUCCHI S.r.l. unico socio [Prod. Cat.: INST - LITE] Via IV Novembre, 30/32 IT-23854 Olginate Lecco (LC) Italy [INST] EN 60998-1:2004 (All clauses except 12.3); EN 60998-2-1:2004 (All clauses except 12.3); EN 60998-2-2:2004 (All clauses except 12.3); EN 61984:2009 (All clauses except 7.3.7, 7.3.9, 7.3.10, 7.3.13, 7.3.14, 7.4.2) [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.20, 4.24 / Annex P, 4.28, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.3); EN IEC 60598-1:2021 (All clauses except 4.13, 4.20, 4.24 / Annex P, 4.28, 4.34, 4.35, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 9.2.11, 9.3); EN 60400:2017 (All clauses except 10.2 (only for soldering lugs)); EN 60838-1:2016 + A1:2017 (All clauses except 8.2 (only for soldering lugs)); EN 60570:2003 + A1:2017 + A2:2020 (All clauses except 12.3, 14) 2006-11-23 2021-05-03 IMQ-071/CTF2-D
E-CTF 2 AB PLAST S.r.l. Via Fura, 38/A IT - 25125 Brescia (BS) Italy [INST] EN 60669-1:2018 (All clauses except 15.2.2 (for degrees of protection higher than IPX4), 15.2.3 (for degree of protection higher than IPX6)) 2021-11-25 2022-11-25 IMQ-402/E-CTF2 Issue No: 1
E-CTF 2 ABB S.p.A. (LABORATORIO PROVE ABB) [Prod. Cat.: EMC] Viale dell'Industria, 18 IT-20010 Vittuone Milano (MI) Italy [EMC] EN 61000-4-2:2009; EN 61000-4-4:2012; EN 61000-4-5:2014 + A1:2017; EN 61000-4-6:2014; EN 61000-4-8:2010 (Only continuous field up to 30 A/m); EN 61000-4-9:2016; EN 61000-4-11:2004 (All clauses (single-phase systems only)); EN IEC 61000-4-11:2020 + AC:2020 (All clauses (single-phase systems only)); EN 61000-4-12:2006; EN 61000-4-16:2016 (All clauses except short duration disturbances); EN 61000-4-20:2010; EN 55011:2016 + A1:2017 + A11:2020 (Accepted sub-slause 8.2 (Conducted Emissions)); EN 55014-1:2006 + A1:2009 + A2:2011 (All clauses except 5.3.2, 5.3.3, 5.4.2); EN 55014-1:2017 + A1:2020 (All clauses except 5.3.2, 5.3.3, 5.4.2); EN 55015:2013 + A1:2015 (Accepted clause 8 (Conducted Emissions); EN IEC 55015:2019 + A11:2020; EN 55032:2015 + A1:2020 + A11: 2020 (Accepted Annex A.3 (Conducted Emissions)); EN IEC 61000-6-1:2019 (All clauses except 1.1 Table 1 (Magnetic Field)); EN IEC 61000-6-2:2019 (All clauses except 1.1 Table 1 (Magnetic Field)); EN 61000-6-3:2007 + A1:2011 (All clauses except tests belonging to IEC 61000-3 series); EN IEC 61000-6-4:2019; EN 61326-1:2013 (All clauses except radiated emission measurement and Electromagnetic field); EN 61557-12:2008 (All clauses except radiated emission measurement and Electromagnetic field); EN 61543:1995 + A11:1995 + A12:2005 + A2:2006 (All clauses except Ref. T 2.5 of Tab. 2 and radiated emission measurements); EN 60947-1:2007 + A1:2011 + A2:2014 (Accepted sub-clause 8.4.1 (except 8.4.1.2.3, 8.4.1.2.7)); EN 60947-2:2006 + A1:2009 + A2:2014 (Accepted Annex J (except J.2.3, J.3.3)); EN 60947-2:2017 (Accepted Annex J (except J.2.3, J.3.3)); EN 61008-1:2012 + A1:2014 + A2:2014 + A11:2015 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 61008-2-1:1994 + A11:1998 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2016 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 61009-2-1:1994 + A11:1998 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 62423:2012 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 62606:2013 + A1:2017 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 60669-2-1:2004 + A1:2009 + A12:2010 (Accepted clause 26 (except 26.1.5, 26.1.7)); EN 60669-2-5:2016 (Accepted clause 26 (except 26.2.6, 26.2.8, 26.3.1, 26.3.4)); EN 50491-5-1:2010 (All clauses except 6.2.2, 6.2.6, 6.3.2, 6.3.3)); EN 50491-5-2:2010 (All clauses except 6.2.2, 6.2.6, 6.3.2, 6.3.3)); EN 50130-4:2011 + A1:2014; ETSI EN 301 489-1 V2.2.3 (All clauses except radiated emission measurement and Electromagnetic field); ETSI EN 301 489-3 V2.1.1 (All clauses except radiated emission measurement and Electromagnetic field); ETSI EN 301 489-17 V3.2.4 (All clauses except radiated emission measurement and Electromagnetic field); CLC/TR 50579:2012; EN 50470-1:2006 + A1:2018 (Accepted clauses 6.3.2, 6.3.3, 6.3.4, 7.3, 7.4.4, 7.4.5, 7.4.7, 7.4.8, 7.4.9, 7.4.13 (limited to conducted tests)); EN 50470-3:2006 + A1:2018 (Accepted clauses 8.1, 8.4, 8.7.2, 8.7.3, 8.7.4, 8.7.5.2, 8.7.5.3, 8.7.5.4, 8.7.6, 8.7.7.2, 8.7.7.3, 8.7.7.4, 8.7.7.5, 9.7.7.7, 8.7.7.8, 8.7.7.9, 8.7.9.3, 8.7.9.4, 8.7.10, 9, 10)); EN 62059-32-1:2012 2017-06-09 2021-03-23 IMQ-308/CTF2-D
E-CTF 3 ABB S.p.A. (LABORATORIO PROVE ABB) [Prod. Cat.: INST - PROT (Protection Devices)] Viale dell'Industria, 18 IT-20010 Vittuone Milano (MI) Italy [INST] EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses except 8.4); EN 60947-3:2009 + A1:2012 [POW] EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses except 8.4); EN 60947-2:2006 + A1:2009 + A2:2013 (All clauses except Annex J); EN 60947-2:2016 (All clauses except Annex J) [PROT] EN 60898-1:2003 + A1:2004 + A11:2005 + A12:2008 + A13:2012; EN 61008-1:2012 + A1:2014 + A2:2014 + A11:2015 (All clauses except H, I, J); EN 61008-2-1:1994 + A11:1998 (All clauses except H, I, J); EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2016 (All clauses except H, I, J); EN 61009-2-1:1994 + A11:1998 (All clauses except H, I, J); EN 62423:2012 (All clauses except H, I, J); EN 62606:2013 + A1:2017 (All clauses except H, I, J); EN 60269-1:2007 + A1:2009 + A2:2014; HD 60269-2:2013; HD 60269-3:2010 + A1:2013 2003-06-19 2019-04-16 IMQ-019/CTF3-C
E-CTF 3 ARISTON THERMO S.p.A. (Laboratorio Prove) Via Pascoli, 1 IT-60044 Fabriano Ancona (AN) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 14, 19.11.4 (EMP), Annex F, Annex G, Annex H, Annex K, Annex R, Annex T, IEC/EN 62233 (EMF)); EN 60335-1:2012 + A11:2014 + A13:2017 (All clauses except 14, 19.11.4 (EMP), Annex F, Annex G, Annex H, Annex K, Annex R, Annex T, IEC/EN 62233 (EMF)); EN 60335-2-21:2003 + A1:2005 + A2:2008; EN 60335-2-35:2002 + A1:2007 + A2:2011; EN 60335-2-40:2003 + A11:2004 + A12:2005 + A1:2006 + A2:2009 + A13:2012 1991-04-08 2021-02-01 IMQ-012/CTF3-C
E-CTF 2 BAXI S.p.A. (R&D LABORATORY) Via Trozzetti, 20 IT-36061 Bassano del Grappa Vicenza (VI) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 (All clauses except 19.11.4 (EMP), 29, 30.1, 30.2); EN 60335-2-102:2006 + A1:2010 (All clauses); EN 60335-2-102:2016 (All clauses); EN 60529:1991 + A1:2000 + A2:2013 (All clauses (only for protection degrees IPX4, IPX5, IPXXD)) 1997-07-18 2019-04-15 IMQ-002/CTF2-D
E-CTF 2 BEGHELLI S.p.A. (Laboratorio Certificazione Beghelli) Via Mozzeghine, 13/15 IT-40053 Valsamoggia - Località Monteveglio Bologna (BO) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 5.2.10, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 10.3.1, 12.5.1e) Annex C Fig. C3, 13.3.1, 13.4.1); EN 60598-2-1:1989; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-5:2015; EN 60598-2-8:2013 (All clauses except 8.11.4.1, 8.16.1); EN 60598-2-22:2014; EN 60598-2-24:2013; EN 61347-1:2015 (All clauses except 14.6, 17, 18.2, 18.4, 18.5, 19, Annex B (B.9.5)); EN 61347-2-7:2012 (All clauses except 4.4.5 of IEC 62034 (prescribed in Annex K)); EN 61347-2-13:2014 + A1:2017; EN 62031:2008 + A1:2013 + A2:2015 (All clauses except 5.5, 7.1.g), 18, 19) 2005-10-10 2020-04-14 IMQ-058/CTF2-E
E-CTF 2 BELLCO S.r.l. (R&D Equipment) Via Camurana, 1 IT-41037 Mirandola Modena (MO) Italy [MED] EN 60601-1:2006 + A1:2012 (All clauses except 5.7, 8.5.5, 8.8.4, 9.5.2, 9.6.2, 9.6.3, 10.1, 10.3, 10.4, 11.2, 11.6.7, 15.4.3.4, 15.4.7, 15.5.2); EN 60601-1-6:2010 + A1:2015; EN 60601-1-8:2007 + A1:2013 (All clauses except 6.3.3); EN 60601-1-16:2015 (All clauses except 208.6.3.3.2) 2010-12-01 2020-03-30 IMQ-203/CTF2-E
E-CTF 2 BOCCHIOTTI S.p.A. Via Pian Masino, 109 IT-16011 Arenzano Genova (GE) Italy [INST] EN 50085-1:2005 + A1:2013; EN 50085-2-1:2006 + A11:2011; EN 50085-2-2:2008 (All clauses except 14.101); EN 50085-2-3:2010; EN 50085-2-4:2009; EN 61386-1:2008 + A1:2019; EN 61386-21:2004 + A11:2010; EN 61386-22:2004 + A11:2010; EN 61386-23:2004 + A11:2010; EN 60670-1:2005 + A1:2013 (All clauses except 19); EN 60670-22:2006; EN 60670-23:2008; EN 60670-24:2013; EN 62208:2011 (All clauses except 9.12, 9.13) 2005-10-10 2020-09-02 IMQ-056/CTF2-C
E-CTF 2 BONFERRARO S.p.A. Via Oberdan, 57 IT-37060 Bonferraro di Sorgà Verona (VR) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 (All clauses except 14, 19.11.4 (EMP), Annex R; Annex T); EN 60335-2-5:2015 + A11:2019 + A1:2020; EN 60335-2-7:2010 + A1:2013 + A11:2013 + A2:2019; EN 60335-2-11:2010 + A11:2012 + A1:2015 + A2:2018 [MEAS] EN 61010-1:2010 (All clauses except 11.6, 12.2.1, 12.2.2, 12.3, 12.4, 12.5.2, 12.6, 13.2.3, 14.8, Annex H); EN 61010-2-040:2015 (All clauses except 7.106, 12.3, 13.1, 13.101) 2001-05-08 2021-09-15 IMQ-004/CTF2-E
E-CTF 2 BRAHMA S.p.A. (Omologation and testing laboratory (LOM)) Via del Pontiere, 31 IT-37045 Legnago (VR) Italy [CONT] EN 60730-1:2000 + A12:2003 + A1:2004 + A13:2004 + A14:2005 + A16:2007 + A2:2008 (All clauses except 18, 21, 22, 23, 28, H26.10, H26.12.3, H26.16); EN 60730-1:2011 (All clauses except 18, 21, 22, 23, 28, H26.10, H26.12.3, H26.16); EN 60730-2-5:2002 + A1:2004 + A11:2005 + A2:2010; EN 60730-2-5:2015 [HOUS] EN 60335-1:2012 + A11:2014 (Accepted clauses 19.11.4.1, 19.11.4.3, 19.11.4.4, 19.11.4.5, 19.11.4.6, 19.11.4.8); EN 60335-2-102:2016 (Accepted clauses 19.11.4.1, 19.11.4.3, 19.11.4.4, 19.11.4.5, 19.11.4.6) 2017-09-08 2020-07-13 IMQ-233/CTF2-B
E-CTF 3 BTICINO S.p.A. (SALA PROVE BTICINO) Viale L. Borri, 231 IT-21100 Varese Varese (VA) Italy [INST] EN 50085-1:2005; EN 50085-2-1:2006 + A1:2011; EN 50085-2-3:2010; EN 50085-2-4:2009; EN 61242:1997 + A1:2008; EN 60309-1:1999 + A1:2007 + A2:2012 (All clauses except 8, 24.2); EN 60309-2:1999 + A1:2007 + A2:2012 (All clauses except 8, 24.2); EN 50250:2002 (All clauses except 8); EN 60669-1:1999 + A1:2002 + A2:2008; EN 60669-1:2018; EN 60669-2-1:2004 + A1:2009 + A12:2010; EN 50428:2005 + A1:2007 + A2:2009 (All clauses except 26.2.3, 26.2.4); EN 60669-2-2:2006; EN 60669-2-3:2006; EN 60669-2-4:2005; EN 60669-2-5:2016 (All clauses except 26.2.3, 26.2.4); EN 62080:2009; EN 62094-1:2003 + A11:2003; EN 60998-1:2004; EN 60998-2-1:2004; EN 60670-1:2005 + A1:2013; EN 60670-22:2008; EN 60670-24:2013; EN 61386-1:2008 + A1:2019 (All clauses except 13.1.3.2); EN 61386-21:2004 + A11:2010; EN 61386-22:2004 + A11:2010; EN 61386-23:2004 + A11:2010; EN 62444:2013 [POW] EN 62019:1999 + A1:2003 + A11:2005 + A12:2014; 2004; EN 60439-1:1999 + A1:2004; EN 61439-1:2011; EN 61439-2:2011; EN 60947-1:2007 + A1:2011 + A2:2014; EN 60947-2:2006 + A1:2009 + A2:2013; EN 60947-2:2017; EN 60947-3:2009 + A1:2012; EN 60947-5-1:2004 + A1:2009 [CONT] EN 60934:2001 + A1:2007 + A2:2013 [PROT] EN 60898-1:2003 + A1:2004 + A11:2005 + A12:2008 + A13:2012; EN 60898-1:2019; EN 61008-1:2012 + A1:2014 + A2:2014; EN 61008-2-1:1994 + A11:1998; EN 61009-1:2012 + A1:2014 + A2:2014; EN 61009-2-1:1994 + A11:1998; EN 62423:2012; EN 50557:2011; EN 61643-11:2012 + A11:2018 2006-03-16 2021-07-16 IMQ-060/CTF3-E
E-CTF 2 BTICINO S.p.A. (SALA PROVE BTICINO) [Prod. Cat.: INST] Strada della Guasca, 201 IT-15122 Spinetta Marengo Alessandria (AL) Italy [INST] EN 61386-1:2008; EN 61386-21: 2004 + A11:2010 (Accepted clause 10.3.1); EN 61386-22: 2004 + A11:2010 (Accepted clauses 10.3.1, 13.1.3.2); EN 61386-23: 2004 + A11:2010 (Accepted clauses 10.3.1, 13.1.3.2); EN 61537:2007 2007-12-31 2021-06-25 IMQ-206/CTF2-C
E-CTF 3 CANDY HOOVER GROUP S.r.l. (Laboratorio Norme) Via Comolli, 16 IT-20861 Brugherio Monza-Brianza (MB) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 14, 19.11.4.2); EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 (All clauses except 14, 19.11.4.2); EN 60335 2-4:2010 + A1:2015; EN 60335-2-5:2015; EN 60335-2-6:2015 + A1:2020 (All clauses except 22.110, 22.111, 22.135, 22.136, 22.137, 32.101); EN 60335-2-7:2010 + A1:2013 + A11:2013; EN 60335-2-11:2010 + A11:2012 + A1:2015 (All clauses except Annex BB); EN 60335-2-102:2016 (All clauses except 8.101); EN 61770:2009 (All clauses except 8, 9) [EMC] EN 62233:2008 2005-01-01 2021-05-07 IMQ-005/CTF3-F
E-CTF 2 Cariboni Group S.p.A. Via della Tecnica, 19 IT-23875 Osnago Lecco (LC) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.4.5, 4.13.6, 4.14.1, 4.14.2, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 8.2.7, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.9, 9.3.1, 12.7.2, 13.3.1, 13.3.2, 13.4.1); EN 60598-2-1:1989; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN 60598-2-24:2013; EN 62031:2008 + A1:2013 + A2:2015 (All clauses except 5.5, 7.1g), 8, 11, 17, 18, 19, Annex A) 2018-04-09 2021-03-23 IMQ-045/CTF2-F
E-CTF 2 CASTALDI LIGHTING S.p.A. Via Benvenuto Cellini, 8 IT-21012 Cassano Magnago Varese (VA) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.4.5, 4.11.6, 4.13.6, 4.18.1, 4.18.2 / Annex F, 4.14.3, 4.20, 4.24 / Annex P, 4.28, 8.2.7, 9.2.1, 9.2.2, 9.2.3, 12.7.2, 13.4.1); EN 60598-2-1:1989; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN 60598-2-18:1994 + A1:2012; EN 62031 :2008 + A1 :2013 + A2 :2015 (All clauses except 5.5, 7.1.g, 13.1, 18, Annex A) 2006-11-27 2020-08-04 IMQ-073/CTF2-E
E-CTF 2 DE’ LONGHI APPLIANCES S.r.l. (Laboratorio CAFFE’) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.48, Annex N, Annex R, Annex T); EN 60335-2-14:2006 + A1:2008 + A11:2012 + A12:2016; EN 60335-2-15:2016 + A11:2018 2006-02-08 2021-02-11 IMQ-066/CTF2-F
E-CTF 2 DE’ LONGHI APPLIANCES S.r.l. (Laboratorio COMFORT) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.48, Annex N, Annex R, Annex T); EN 60335-2-30:2009 + A11:2012 + A1:2020 + A12:2020; EN 60335-2-43:2003 + A1:2006 + A2:2008; EN IEC 60335-2-43:2020 + A11:2020; EN 60335-2-65:2003 + A1:2008 + A11:2012 (All clauses except 32, Annex AA); EN 60335-2-80:2003 + A1:2004 + A2:2009 2005-07-05 2021-02-11 IMQ-029/CTF2-G
E-CTF 2 DE’ LONGHI APPLIANCES S.r.l. (Laboratorio COTTURA) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.48, Annex N, Annex R, Annex T); EN 60335-2-9:2003 + A1:2004 + A2:2006 + A12:2007 + A13:2010; EN 60335-2-13:2010 + A11:2012 + A1:2019; EN 60335-2-15:2016 + A11:2018 2006-02-08 2021-06-08 IMQ-067/CTF2-G
E-CTF 2 DE’ LONGHI APPLIANCES s.r.l. (Laboratorio STIRO & PULIZIA) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 (All clauses except 14, 15.1, 15.2, 19.11.4 (EMP), 22.48, Annex N, Annex R, Annex T); EN 60335-2-2:2010 + A11:2012 + A1:2013 (All clauses except 21); EN 60335-2-3:2016 + A1:2020 2006-07-11 2021-02-11 IMQ-096/CTF2-F
E-CTF 2 DISANO ILLUMINAZIONE S.p.A. (Laboratorio Misure e Prove) Via Scaldasole, 8 IT-27020 Dorno Pavia (PV) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.11.6, 4.13.4, 4.13.6, 4.14.3, 4.18.1, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 9.2.3, 9.3.1, 12.7.2, 13.3.1, 13.4.1); EN IEC 60598-1:2021 (All clauses except 4.4.4, 4.11.6, 4.13.4, 4.13.6, 4.14.3, 4.18.1, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 4.36, 9.2.3, 9.2.9, 9.2.10, 9.2.11, 9.3.1, 12.7.2, 13.3.1, 13.4.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 (All clauses except 13.6.2.1, 13.6.2.2); EN 60598-2-22:2014 + A1:2020 (All clauses except 22.17.5 Annex C); EN 62031:2008 + A1:2013 + A2:2015 (All clauses except 5.5, 7.1g), 8, 11, 17, 18, 19, Annex A); EN IEC 62031:2020 (All clauses except 4.8, 6.2 g), 7, 10, 16, 17, 18, 20, 21, Annex A, Annex D); EN 62262:2002 (All clauses [Test Ehb (Spring hammer) and Test Ehc (Vertical hammer) according to IEC/EN 60068-2-75:2014)] [EMC] EN 61547:2009 (All clauses except 5.2, 5.3, 5.4, 5.6); EN 61000-3-2:2014; EN 61000-3-3:2013; EN 55015:2013 + A1:2015 (All clauses except 7, 8.1.2, 8.1.3, 9.2) 2005-08-02 2021-06-15 IMQ-037/CTF2-G
E-CTF 2 DUCATI ENERGIA S.p.A. Via M.E. Lepido, 182 IT-40132 Bologna Bologna (BO) Italy [CAP] EN 60252-1:2011 + A1:2013 (Accepted clauses 5.5, 5.7, 5.8, 5.9, 5.12, 5.13, 5.15, 5.16); EN 60252-2:2011 + A1:2013 (Accepted clauses 6.1.6, 6.1.7, 6.1.8, 6.1.11, 6.1.12, 6.1.14); EN 60831-1:2014 (Accepted clauses 7, 8, 9, 10, 11, 12, 13, 14, 15, 16); EN 60831-2:2014 (Accepted clauses 17, 18, 19); EN 61048:2006 (Accepted clauses 12, 13, 14, 17, 18.1.1, 18.1.2, 18.1.4, 18.2, 18.3); EN 61049:1993 (Accepted clauses 6, 8) 2005-11-22 2018-12-10 IMQ-080/CTF2-C
E-CTF 2 ELECTROLUX PROFESSIONAL S.p.A. (Cooking Laboratory) Viale Treviso, 15 IT-33170 Pordenone Pordenone (PN) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 14, 15, 19.11.4 (EMP), 21.2, 22.48, 29.2.1, 30.1, 30.2, Annex E, Annex F, Annex G, Annex H, Annex K, Annex N, Annex R, Annex T); EN 60335-1:2012 + A11:2014 + A13:2017 (All clauses except 14, 15, 19.11.4 (EMP), 21.2, 22.48, 29.2.1, 30.1, 30.2, Annex E, Annex F, Annex G, Annex H, Annex K, Annex N, Annex R, Annex T); EN 60335-2-6:2015 (All clauses except 22.110, 22.111, 30, 32.101); EN 60335-2-36:2002 + A1:2004 + A2:2008 + A11:2012; EN 60335-2-37:2002 + A1:2008 + A11:2012; EN 60335-2-38:2003 + A1:2008; EN 60335-2-39:2003 + A1:2004 + A2:2008; EN 60335-2-42:2003 + A1:2008 + A11:2012; EN 60335-2-47:2003 + A1:2008 + A11:2012; EN 60335-2-48:2003 + A1:2008 + A11:2012; EN 60335-2-50:2003 + A1:2008; EN 60335-2-64:2000 + A1:2002; EN 60335-2-90:2006 + A1:2010; EN 60335-2-102:2016 (All clauses except 8.101) 2010-09-30 2019-10-15 IMQ-199/CTF2-E
E-CTF 2 ELECTROLUX PROFESSIONAL S.p.A. (Refrigeration Laboratory) Viale Treviso, 15 IT-33170 Pordenone Pordenone (PN) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 (All clauses except 14, 15, 19.11.4 (EMP), 21.2, 22.48, 29.2.1, 30.1, 30.2, Annex N, Annex T); EN 60335-2-89:2010 + A1:2016 + A2:2017 (All clauses except 15.102, 22.104, 22.106, 22.107, 22.108) 2019-02-28 2020-08-24 IMQ-353/CTF2-A
E-CTF 2 ELETTROTECNICA ROLD S.r.l. Via della Merlata, 1 IT-20014 Nerviano Milano (MI) Italy [CONT] EN 60730-1:2011 (All clauses except 23, 26, Annex H); EN 60730-1:2016 (All clauses except 23, 26, Annex H); EN 60730-2-12:2006 + A11:2008 (All clauses except 23, 26, Annex H); EN IEC 60730-2-12:2019 (All clauses except 23, 26, Annex H) [INST] EN 61058-1:2002 + A2:2008 (All clauses except 10.4, 11.2.7, 14.1, 14.2, 14.3, 19.2.4, 19.2.5, 23, 25); EN IEC 61058-1:2018 (All clauses except 10.4, 14.1, 14.2, 14.3, 19.2.4, 19.2.5, 23, 25); EN 61058-1-1:2016 (All clauses except 23) 2005-07-07 2021-06-21 IMQ-031/CTF2-F
E-CTF 2 EMBRACO SLOVAKIA s.r.o.(Electrical Laboratory) Odorínska Cesta, 2 SK-05201 Spi?ská Nová Ves Slovakia [HOUS] EN 60335 1:2012 + A11:2014 + A13:2017 (Accepted clauses: 7, 13.3, 16, 19 (except 19.11.4), 22.7, 22.9, 24.5, 30.1); EN 60335-2-34:2013 (Accepted clauses: 7, 13.3, 16, 19 (except 19.11.4), 22.7, 22.9, 22.101, 24.5, 30.1, Annex AA) 2007-08-01 2021-06-09 IMQ-116/CTF2-B
E-CTF 2 EVOCA S.p.A. (Laboratorio Ricerca e Sviluppo) Via Roma, 24 IT-24030 Valbrembo Bergamo (BG) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 14, 15.1, 19.11.4, 21.1, 22.3, 22.12, 22.32, 22.48, 23.3, 25.14, 26.3, 28.1, 29.2, 30, Annex T); EN 60335-1:2012 + A11:2014 + A13:2017 (All clauses except 14, 15.1, 19.11.4, 21.1, 22.3, 22.12, 22.32, 22.48, 23.3, 25.14, 26.3, 28.1, 29.2, 30, Annex T); EN 60335-2-24:2010 + A1:2019 + A2:2019 (Accepted clauses 7, 10, 11, 19, 22.104, 22.105, 22.112, 22.113, 22.114, 22.115, 24, Annex AA); EN 60335-2-75:2004 + A1:2005 + A11:2006 + A2:2008 + A12:2010 (All clauses except 15.1.1, 22.47) 2018-01-10 2021-03-16 IMQ-143/CTF2-F
E-CTF 2 FABER S.p.A. (R&D Laboratory) Viale XIII Luglio, 160 IT-60044 Fabriano Fabriano (AN) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.48); EN 60335-2-6:2015; EN 60335-2-31:2014 2006-03-24 2021-04-06 IMQ-093/CTF2-I
E-CTF 2 FANTON S.p.A. Viale dell’Industria, 8/10IT-35026 ConselvePadova (PD) Italy [INST] EN 61242:1997 + A1:2008 + A2:2016 + A13:2017 2005-09-22 2020-10-06 IMQ-044/CTF2-D
E-CTF 2 FINDER S.p.A. Via Drubiaglio, 14 IT-10040 Almese Torino (TO) Italy [INST] EN 60669-1:1999 + A1:2002 + A2:2008 (All clauses except 15.2, 20, 24.2, 26); EN 60669-2-1:2004 + A1:2009 + A12:2010 (All clauses except 15.2, 20, 24.2, 26); EN 60669-2-2:2006 ( (All clauses except 15.2, 20, 24.2, 26) [CONT] EN 61810-1:2015 (All clauses except 13); EN 61810-3:2015; EN 61095:2009 (All clauses except 9.3.3.4.1 item b (Impulse withstand voltage test), 9.3.4); EN 60730-1:2011 (Accepted clauses 12, 13, 14, 15, 16, 17) 2006-02-21 2019-04-11 IMQ-068/CTF2-D
E-CTF 2 FISHER & PAYKEL APPLIANCES ITALY S.p.A. (Laboratorio Ricerca e Sviluppo) Via Fabbian Matteo, 7 IT-31030 Borso del Grappa Treviso (TV) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 19.11.4 (EMP), 30, Annex E, Annex N); EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019 (All clauses except 19.11.4 (EMP), 30, Annex E, Annex N); EN 60335-2-6:2015 + A11:2020 + A1:2020 (All clauses except 22.110, 22.111, 29, 30.1, 30.2, 32.101); EN 60335-2-13:2010 + A11:2012; EN 60335-2-102:2016 (All clauses except 8.101) 2009-03-31 2021-02-23 IMQ-150/CTF2-E
E-CTF 2 FLOS S.p.A. Via Angelo Faini, 2 IT-25073 Bovezzo Brescia (BS) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.4.5, 4.13.4, 4.13.6, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 9.3.1, 13.3.1); EN IEC 60598-1:2021 (All clauses except 4.4.4, 4.4.5, 4.13.4, 4.13.6, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 4.36, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 9.2.11, 9.3.1, 13.3.1); EN 60598-2-1:1989; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN 60598-2-23:1996 + A1:2000; EN 60598-2-24:2013 2005-09-22 2021-04-20 IMQ-043/CTF2-F
E-CTF 3 GEWISS S.p.A. [Cenate Sotto] Via A. Volta, 1 IT-24069 Cenate Sotto Bergamo (BG) Italy [INST] EN 50085-1:2005 + A1:2013; EN 50085-2-1:2006 + A1:2011; EN 50085-2-3:2010; EN 61386-1:2008 (All clauses (only for accessories)); EN 61386-21:2004 + A11:2010 (All clauses (only for accessories)); EN 61386-22:2004 + A11:2010 (All clauses (only for accessories)); EN 61386-23:2004 + A11:2010 (All clauses (only for accessories)); EN 61386-24:2010 (All clauses (only for accessories)); EN 60309-1:1999 + A1:2007 + A2:2012; EN 60309-2:1999 + A1:2007 + A2:2012; EN 60309-4:2007 + A1:2012; EN 50250:2002 + A1:2015; EN 60669-1:1999 + A1:2002 + A2:2008; EN 60669-1:2018; EN 60669-2-1:2004 + A1:2009 + A12:2010 (All clauses except 26); EN 60669-2-2:2006 (All clauses except 26); EN 60669-2-3:2006 (All clauses except 26); EN 60669-2-4:2005; EN 62094-1:2003 + A11:2003; EN 60998-1:2004; EN 60998-2-1:2004; EN 60670-1:2005 + A1:2013; EN 60670-22:2006; EN 60670-24:2013; EN 62208:2011; EN 61984:2009 (All clauses except 7.3.14) [POW] EN 60947-1:2007 + A1:2011 + A2:2014; EN 60947-2:2006 + A1:2009 + A2:2013 (All clauses except Annex J); EN 60947-2:2017 (All clauses except Annex J); EN 60947-3:2009 + A1:2012 + A2:2015; EN 60947-5-1:2017; EN 61439-1:2011; EN 61439-2:2011; EN 61439-3:2012; EN 61439-4:2013; EN 61439-5:2015; EN 61439-6:2012; EN 62019:1999 + A1:2003 + A11:2005 + A12:2014 [CONT] EN 61095:2009 [PROT] EN 60898-1:2003 + A1:2004 + A11:2005 + A12:2008 + A13:2012; EN 61008-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (All clauses except test sequences H, I, J); EN 61008-2-1:1994 + A11:1998 (All clauses except test sequences H, I, J); EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (All clauses except test sequences H, I, J); EN 61009-2-1:1994 + A11:1998 (All clauses except test sequences H, I, J); EN 62423:2012 (All clauses except test sequences H, I, J); EN 63024:2018 (All clauses except test sequence G) [ELVH] EN 62196-1:2014 (All clauses except 26.4); EN 62196-2:2017 (All clauses except 26.4); EN IEC 61851-1:2019 2001-09-12 2021-06-17 IMQ-008/CTF3-G
E-CTF 3 GEWISS S.p.A. [Cenate Sopra] Via Provinciale, 61 IT-24060 Cenate Sopra Bergamo (BG) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.13.4, 4.14.1, 4.20, 4.24 / Annex P, 4.26, 9.2.9); EN 60598-2-1:1989; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-22:2014 (All clauses except 22.17.1 Annex C); EN 60598-2-24:2013; EN 61347-1:2015; EN 61347-2-7:2012; EN 61347-2-13:2014 (All clauses except I.6.3.3); EN 62031:2008 + A1:2013 + A2:2015 (All clauses except 5.5, 7.1g); EN IEC 62031:2020 (All clauses except 21, Annex D) 2020-07-07 0000-00-00 IMQ-374/CTF3
E-CTF 2 GEWISS S.p.A. (Laboratorio di Compatibilità Elettromagnetica) [Prod. Cat.: EMC] Via A. Volta, 1 IT-24069 Cenate Sotto Bergamo (BG) Italy [EMC] EN 50491-5-2:2010 (Excluded radiated immunity and emission test); EN 50491-5-3:2010 (Excluded radiated immunity and emission test); EN 50557:2011 (Accepted clause 26 (excluded radiated immunity and emission test)); EN 55014-1:2006 + A1:2009 + A2:2011 (Excluded radiated emission test); EN 55014-1:2017 (Excluded radiated emission test); EN 55014-2:2015 (Excluded radiated immunity test); EN 55015:2013 + A1:2015 (Excluded radiated emission test); EN 60669-2-1:2004 + A1:2009 + A12:2010 (Accepted clause 26 (excluded radiated immunity and emission test)); EN 60669-2-5:2016 (Accepted clause 26 (excluded radiated immunity and emission test)); EN 60947-1:2007 + A1:2011 + A2:2014 (Accepted sub-clause 7.3 (excluded radiated emission test and only sub-clause 8.4.1 except 8.4.1.2.3)); EN 60947-2:2006 + A1:2009 + A2:2013 (Accepted sub-clause 7.3 (excluded radiated emission test and only Annex J except J.2.3)); EN 60947-2:2017 (Accepted sub-clause 7.3 (excluded radiated emission test and only Annex J except J.2.3)); EN 61000-3-2:2014; EN 61000-3-3:2013; EN 61000-6-1:2007 (Excluded radiated immunity test); EN 61000-6-2:2005 (Excluded radiated immunity test); EN 61000-6-3:2007 + A1:2011 (Excluded radiated emission test); EN 61000-6-4:2007 + A1:2011 (Excluded radiated emission test); EN 61543:1995 + A11:1995 + A12:2005 + A2:2006 (Accepted clauses 4, 5 (except clause 4 Ref. T 2.5 of Tab. 5)); EN 61547:2009 (Excluded radiated immunity test); EN 62493:2015 (Excluded radiated immunity test); EN 61008-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2016 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J) 2017-09-25 2018-12-05 IMQ-145/CTF2-A
E-CTF 2 GEWISS S.p.A. (Laboratorio Prove GW130) Via Emilia Pavese, 53 IT-29015 Castel San Giovanni Piacenza (PC) Italy [INST] EN 61386-1:2008 (All clauses except 14); EN 61386-21:2004 + A11:2010 (All clauses except 14); EN 61386-22:2004 + A11:2010 (All clauses except 14); EN 61386-23:2004 + A11:2010 (All clauses except 14); EN 61386-24:2010 (All clauses except 14) 2016-04-13 2019-06-03 IMQ-284/CTF2-B
E-CTF 3 HAGER ELECTRO SAS Boulevard d'Europe, 132 FR-67210 CEDEX Obernai France [INST] EN 60669-1:1999 + A1:2002 + A2:2008; EN 60669-1:2018; EN 60669-2-2:2006; EN 60669-2-4:2005 [POW] EN 60947-2:2017; EN 60947-3:2009 + A1:2012 + A2:2015; EN 60947-4-1:2010 + A1:2012; EN 60947-5-1:2004 + A1:2009 [CONT] EN 61095:2009 2010-04-14 2020-02-24 IMQ-188/CTF3-C
E-CTF 1 ICEL S.r.l. (LABORATORIO E SALA PROVE ICEL) Via Carlo Jucker, 16 IT-21053 Castellanza Varese (VA) Italy [CAP] EN 60252-1:2011 + A1:2013 (Accepted clauses 5.5, 5.9, 5.13, 5.14) 2005-09-30 2019-07-26 IMQ-048/CTF1-D
E-CTF 2 IGUZZINI ILLUMINAZIONE S.p.A. (Laboratorio Normativo/Sicurezza) Via Mariano Guzzini, 37 IT-62019 Recanati Macerata (MC) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.13.6, 4.20, 4.24 / Annex P, 4.28, 9.2.9, 13.3.1); EN 60598-2-1:1989; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016; EN 60598-2-22:2014 + A1:2020; EN 60598-2-24:2013; EN 62031:2008 + A1:2013 + A2:2015 (All clauses except 5.5, 7.1g), 8, Annex A); EN 62031:2020 (All clauses except 7, 21.1, Annex A, Annex D); EN 60570:2003 + A1:2018 + A2:2020; IEC TR 62778:2014 [EMC] EN 61000-3-2:2014; EN 61000-3-3:2013; EN 55015:2013 + A1:2015 (All clauses except: - No. 7 Method of insertion loss measurement - No. 9 Method of radiated electromagnetic disturbances (semi-anechoic chamber)); EN 61000-4-5:2014 1992-02-07 2021-04-14 IMQ-011/CTF2-G
E-CTF 2 INCO MASSALOMBARDA S.r.l. (LABORATORIO SALA PROVE) Via Marchetti, 88 IT-48024 Massa Lombarda Ravenna (RA) Italy [CAP] EN 60252-1:2011 + A1:2013 (Accepted clauses 5.5, 5.7, 5.8, 5.9, 5.12, 5.13, 5.15, 5.16); EN 61048:2006 (Accepted clauses 12, 13, 14, 17, 18.1.1, 18.1.2, 18.1.4, 18.2, 18.3); EN 61049:1993 (Accepted clauses 6, 8) 2005-09-30 2020-07-31 IMQ-050/CTF2-C
E-CTF 2 ITW Appliance Components S.r.l. (ITW EMEA Laboratory) Via Oltrona, 23 IT-21020 Barasso (VA) Italy EN 60998-1:2004 (All clauses except 12.3); EN 60998-2-1:2004; EN 60998-2-2:2004; EN 61058-1:2016 (Only for mechanical switches - Only for resistive-motor load); EN 61058-1-1:2016 (Only for mechanical switches - Only for resistive-motor load); EN 61058-2-4:2005; EN 60335-1:2012 + A11:2014 (Only clauses 25.15, 28, 30 (except 30.2.4), Annex N) 2018-09-20 2021-03-03 IMQ-343/CTF2-C
E-CTF 2 IVELA S.p.A. Via Bruno Buozzi, 15 IT-20060 Liscate Milano (MI) Italy [LITE] EN 60598-1:2015 (All clauses except 4.4.4, 4.4.5, 4.9.2, 4.12.5, 4.13.4, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.28, 5.2.10.1, 8.2.7, 9.2.1, 9.2.2, 9.2.3, 9.3.1, 10.3.1, 11.2.1, 13.3.1, 13.4.1); EN 60598-2-1:1989; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN 60570:2003 + A1:2018 (All clauses except 12.3.1, 14) 2005-09-23 2021-03-24 IMQ-047/CTF2-F
E-CTF 2 KEMET ELECTRONICS CORPORATION - KEMET ELECTRONICS ITALIA S.r.l. Via Sagittario, 1/3 IT-40037 Sasso Marconi Bologna (BO) Italy [CAP] EN 60252-1:2011 + A1:2013 (Accepted clauses 5.5, 5.7, 5.8, 5.9, 5.12, 5.13, 5.14, 5.15, 5.16); EN 60252-2:2011 + A1:2013 (All clauses except 5.1.17, 6); EN 60384-14:2005 (Accepted clauses 4.1, 4.2, 4.3, 4.4, 4.11, 4.12, 4.13, 4.14, 4.15, 4.17, 4.18, 4.20); EN 60384-14:2013 + A1:2016 (Accepted clauses 4.1, 4.2, 4.3, 4.4, 4.11, 4.12, 4.13, 4.14, 4.15, 4.17, 4.18, 4.20); EN 60831-1:1996 + A1:2003 (Accepted clauses 7, 8, 9, 10, 11, 12, 13, 14, 15, 16); EN 60831-1:2014 (Accepted clauses 7, 8, 9, 10, 11, 12, 13, 14, 15, 16); EN 60831-2:1996 (Accepted clauses 17, 18, 19); EN 60831-2:2014 (Accepted clauses 17, 18, 19); EN 61048:2006 + A1:2016 (Accepted clauses 13, 14, 15, 17, 18); EN 61049:1993 (Accepted clauses 6, 8) 2005-09-30 2020-05-04 IMQ-052/CTF2-C
E-CTF 2 LOVATO ELECTRIC S.p.A. (LABORATORIO DI PROVA (LPR)) Via Don Emilio Mazza, 12 IT-24020 Gorle (BG) Italy EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses except 8.4); EN 60947-3:2009 + A1:2012 + A2:2015 (All clauses except 8.4); EN 60947-4-1:2018 (All clauses except 9.4); EN 60947-5-1:2016 (All clauses except 8.4) 2017-11-06 2020-10-16 IMQ-311/CTF2-A
E-CTF 2 MENEGHETTI S.p.A. Via Generale Cadore, 26 IT-21010 Cardano al Campo (VA) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 8, 14, 15.1, 15.3, 19.11.4, 22.11, 22.12, 22.16, 25.14, 25.15, 26, 28, 30); EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019 (All clauses except 8, 14, 15.1, 15.3, 19.11.4, 22.11, 22.12, 22.16, 25.14, 25.15, 26, 28, 30); EN 60335 2-6:2015 + A1:2020 + A11:2020 (All clauses except 19.101, 19.102, 21.102, 22.110, 22.111, 22.135, 22.136, 30, 32.101); EN 60335-2-102:2016 (All clauses except 8.101) 2018-09-17 2020-07-20 IMQ-342/CTF2-A
E-CTF 2 ODE S.r.l. (LABORATORIO ODE) Via Borgofrancone, 18 IT-23823 Colico Lecco (LC) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019 (Accepted clauses 7, 10, 11, 13.3, 16.3, 26, 29) 2011-09-23 2021-05-13 IMQ-223/CTF2-F
E-CTF 2 PALAZZOLI S.p.A. (LABORATORIO ESPERIENZE) Via F. Palazzoli, 31 IT-25128 Brescia Brescia (BS) Italy [INST] EN 60309-1:1999 + A1:2007 + A2:2012 (All clauses except 10, 12, 20, 21, 29, 30); EN 60309-2:1999 + A1:2007 + A2:2012 (All clauses except 10, 12, 16, 20, 21, 29); EN 60309-4:2007 + A1:2012 (All clauses except 9, 10, 20, 21) 2006-03-16 2017-09-26 IMQ-062/CTF2-B
E-CTF 2 PERFORMANCE IN LIGHTING S.p.A. Viale del Lavoro, 9/11 IT-37030 Colognola ai Colli Verona (VR) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.13.6, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 9.2.3, 10.3.1, 11.2.1); EN 60598-2-1:1989; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN 62031:2008 + A1:2013 + A2:2015 (All clauses except 5.5, 7.1g), 13.1, 18, 19) 2005-04-14 2020-11-02 IMQ-021/CTF2-E
E-CTF 2 PERFORMANCE IN LIGHTING S.p.A. (former S.B.P. S.p.A.) Via Provinciale, 57 IT-24050 Ghisalba Bergamo (BG) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.4.5, 4.11.6, 4.13.6, 4.14.1, 4.14.3, 4.18.1, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 8.2.7, 9.2.3, 10.3.1, 12.7.2, 13.3.1, 13.4.1); EN 60598-2-1:1989; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 (All clauses except 13.6.1,13.6.2.1, 13.6.2.2); EN 60598-2-18:1994 + A1:2012; EN 60598-2-24:2013 2020-02-21 2021-08-31 IMQ-075/CTF2-F
E-CTF 2 PIZZATO ELETTRICA S.r.l. (Laboratorio Prove P6) Corso della Ceramica, 56/B IT-36063 Marostica Vicenza (VI) Italy [POW] EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses except 8.2.1.1.1, 8.3.4, 8.4.1.2.2, 8.4.1.2.3, 8.4.1.2.6, 8.4.1.2.7, 8.4.2 - For Annex C (Degrees of protection of enclosed equipment): Applicable clauses 14.2.4, 14.2.5, 14.2.6, 14.2.7, 14.2.8 of EN 60529:1991 + A1:2000 + A2:2013); EN 60947-5-1:2004 + A1:2009 (All clauses except 8.3.4); EN 60947-5-1:2017 (All clauses except 8.2.1.1.1, 8.3.4, 8.4.2.1, 8.4.2.2, 8.4.2.5, 8.4.2.6, 8.4.3) 2020-09-02 0000-00-00 IMQ-375/CTF2
E-CTF 2 RELCO S.r.l. Via delle Azalee, 6/A IT - 20090 Buccinasco (MI) Italy [LITE] EN 60598-1:2015 + A1:2018 (Accepted clauses 3, 7, 10.2, 11, 12); EN IEC 60598-1:2021 + A11:2022 (Accepted clauses 3, 7, 10.2, 11, 12); EN 60598-2-2:2012 (Accepted clauses 2.6, 2.8, 2.9, 2.13, 2.15); EN 60598-2-3:2003 + A1:2011 (Accepted clauses 3.5, 3.7, 3.8, 3.12, 3.14); EN 60598-2-5:2015 (Accepted clauses 5.5, 5.7, 5.8, 5.12, 5.14); EN 61347-1:2015 + A1:2021 (Accepted clauses 7, 9, 12, 13, 15, 16, 20); EN 61347-2-7:2012 + A1:2019 (All clauses except 8, 9, 11, 14, 15, 16, 17, 18, 19, 20.1, 31, 32, 33, 34.2, 34.5, 35); EN 61347-2-13:2014 + A1:2017 (Accepted clauses 7, 10, 12, 13, 15, 17, 21, Annex J (except J.7, J.8)) 2022-03-25 0000-00-00 IMQ-416/E-CTF2 Issue No: 0
E-CTF 2 SCAME PARRE S.p.A. Via Campignano, 9 IT-24020 Parre Bergamo (BG) Italy [INST] EN 50085-1:2005 + A1:2013; EN 50085-2-1:2006 + A1:2011; EN 61386-1:2008 + A1:2019; EN 61386-21:2004 + A11:2010; EN 61242:1997 + A1:2008 + A2:2016 + A13:2017; EN 60309-1:1999 + A1:2007 + A2:2012 (All clauses except 20 and 21 (for equipment with rated operating voltage > 400V and rated current > 32A)); EN 60309-2:1999 + A1:2007 + A2:2012; EN 60309-4:2007 + A1:2012; EN 61316:1999; EN 50250:2002 + A1:2015; EN 60669-1:1999 + A1:2002 + A2:2008; EN 60669-1:2018 (All clauses except 19.3); EN 60998-1:2004; EN 60998-2-1:2004; EN 60670-1:2005 + A1:2013; EN 60670-22:2006; EN 60670-24:2013; EN 62208:2011 (All clauses except 9.13) [ELVH] EN 62196-1:2012 + A11:2013 + A12:2014 (All clauses except 22, 23 and 31); EN 62196-1:2014 (All clauses except 22, 23 and 31); EN 62196-2:2012 + A11:2013 + A12:2014; EN 62196-2:2017 [POW] EN 61439-1:2011 (All clauses except 10.2.2); EN 61439-4:2013 (All clauses except 10.2.6.3, 10.2.2.101); EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses except 8.3.3); EN 60947-3:2009 + A1:2012 + A2:2015 (All clauses except 8.3.3, 8.3.5, 8.3.6) 2005-11-11 2021-06-16 IMQ-069/CTF2-D
E-CTF 2 SCHNEIDER ELECTRIC INDUSTRIE ITALIA S.p.A. Via Govoni, 17 IT-40066 Pieve di Cento Bologna (BO) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.12.5, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 9.2.1, 9.2.2, 9.2.7, 9.2.8, 9.2.9, 10.3.1, 12.5.1e), Annex C Fig. C3); EN IEC 60598-1:2021 (All clauses except 4.4.4, 4.12.5, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 4.36, 9.2.1, 9.2.2, 9.2.5, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 9.2.11, 10.3, 12.5 1e), Annex C Fig. C3); EN 60598-2-1:1989; EN 60598-2-2:2012; EN 60598-2-4:2018; EN 60598-2-22:2014 + A1:2020; EN 61347-1:2015 + A1:2021 (All clauses except 14.6, 17, 18.2, 19); EN 61347-2-7:2012 + A1:2019 (All clauses except 4.4.5 of IEC 62034 (prescribed in Annex K)); EN 62262:2002 (All clauses [Test Eha (Pendulum hammer) according to IEC/EN 60068-2-75:2014)] 2006-02-22 2021-06-18 IMQ-090/CTF2-H
E-CTF 2 SIMES S.p.A. Via G. Pastore, 2/4 IT-25040 Nigoline di Corte Franca Brescia (BS) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.13.6, 4.20, 4.24 / Annex P, 4.26, 4.28, 5.2.10.1, 13.4.1); EN IEC 60598-1:2021 (All clauses except 4.4.4, 4.13.6, 4.20, 4.24.1 / Annex P, 4.26, 4.28, 4.34, 4.35, 4.36, 5.2.10.1, 9.2.10, 9.2.11, 13.4.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016; EN 60598-2-18:1994 + A1:2012; EN 62031:2008 + A1:2013 + A2:2015 (All clauses except 5.5, 18, Annex A); EN IEC 62031:2020 (All clauses except 4.8, 13.1, 18, 20, 21.1/21.3, Annex A, Annex D); IEC/TR 62778:2014 2010-01-21 2021-07-08 IMQ-236/CTF2-G
E-CTF 2 TARGETTI SANKEY S.p.A. (LABORATORIO PROVE TARGETTI) Via Pratese, 164 IT-50145 Firenze Firenze (FI) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.9.2, 4.11.6, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.28, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.3.1, 11.2.1, 12.7.2, 13.4.1); EN 60598-2-1:1989; EN 60598-2-2:2012; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016; EN 62031:2008 + A1:2013 + A2:2015 (All clauses except 5.5, 7.1g), 8, 11, 17, 18, 19, Annex A) 1994-01-26 2020-06-03 IMQ-014/CTF2-E
E-CTF 1 TECNOINOX S.r.l. (Laboratorio TECNOINOX) Via Torricelli, 1 IT - 33080 Porcia (PN) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 8, 14, 15, 19.11.4 (EMP), 22, 25, 26, 27, 28, 30, Annex E, Annex N, Annex T); EN 60335-1:2012 + A11:2014 + A13:2017 (All clauses except 8, 14, 15, 19.11.4 (EMP), 22, 25, 26, 27, 28, 30, Annex E, Annex N); EN 60335-2-48:2003 + A1:2008 + A11:2012 (All clauses ) 2018-10-05 0000-00-00 IMQ-344/CTF1
E-CTF 2 TECNOSUPERIORE S.r.l. (Laboratorio TECNOSUPERIORE) [former TECNO S.r.l. (Laboratorio TECNO)] Strada Provinciale 63R 111 IT-42044 Gualtieri Reggio Emilia (RE) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A14:2019 + A1:2019 + A2:2019 (All clauses except 8, 14, 15.1, 15.3, 19.11.4 (EMP), 22.12 (small part cylinder) 25.14, 25.15, 26.6, 28, 29, 30, Annex E, Annex N); EN 60335-2-6:2015 (All clauses except 19.11.4, 19.101, 19.102, 19.103, 28, 29, 30, 32.101); EN 60335-2-102:2016 (All clauses except 8.101, 15.101, 22.103) 2009-12-17 2021-03-16 IMQ-175/CTF2-E
E-CTF 2 TEKA INDUSTRIAL S.A. (TEKA Laboratory Gas Competence Center) Via Alcide De Gasperi, 20 IT-36060 Pianezze San Lorenzo Vicenza (VI) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 8, 14, 15.1, 15.3, 19.11.4, 21.2, 22.11, 22.12, 22.16, 25.14, 25.15, 26, 28, 29, 30); EN 60335-1:2012 + A11:2014 + A13:2017 (All clauses except 8, 14, 15.1, 15.3, 19.11.4, 21.2, 22.11, 22.12, 22.16, 25.14, 25.15, 26, 28, 29, 30); EN 60335-2-6:2015 (All clauses except 8, 19.101, 19.102, 21.102, 22.110, 22.111, 22.135, 22.136, 30, 32.101); EN 60335-2-102:2016 (All clauses except 8.101) 2022-06-13 0000-00-00 IMQ-418/E-CTF2 Issue No: 0
E-CTF 2 THERMOWATT S.p.A. (LABORATORIO THERMOWATT ARCEVIA ELETTROMECCANICA) Via San Giovanni Battista, 21 IT-60011 Arcevia (AN) Italy [CONT] EN 60730-1:2011 (All clauses except 12.1, 18, 21.2.1 to 21.2.4, 21.2.7, 23, 26 and Annexes C-E-H-J-P-Q-R-U); EN 60730-1:2016 + A1:2019 (All clauses except 12.1, 18, 21.2.1 to 21.2.4, 21.2.7, 23, 26 and Annexes C-E-H-J-P-Q-R-U); EN 60730-2-9:2010 (All clauses except 12.1, 18, 21.2.1 to 21.2.4, 21.2.7, 23, 26 and Annexes C-E-H-J-P-Q-R-U-DD); EN IEC 60730-2-9:2019 + A1:2019 (All clauses except 12.1, 18, 21.2.1 to 21.2.4, 21.2.7, 23, 26 and Annexes C-E-H-J-P-Q-R-U-DD) 2017-09-13 2020-03-26 IMQ-207/CTF2-A
E-CTF 2 VIABIZZUNO S.r.l. (Laboratorio Prove Viabizzuno) Via L. Romagnoli, 10 IT-40010 Bentivoglio (BO) Italy [LITE] EN 60598-1:2015 + A1:2018 (Accepted clauses: 3.4, 4.11.6, 4.12.1, 4.12.5, 4.13.1, 4.13.3, 4.21.4, 4.26, 5.2.10.1, 5.3, 5.4, 7.2.3, 8.2.5, 9.2.0, 10.2.1, 10.2.2, 10.2.3, 11.2.1, 12.3.1, 12.4.1, 12.5.1 e), Annex C Fig. C3, 14, 4.6.3, 4.12); EN IEC 60598-1:2021 (Accepted clauses: 3.4, 4.11.6, 4.12.1, 4.12.5, 4.13.1, 4.13.3, 4.21.4, 4.26, 4.33, 4.36, 5.2.10.1, 5.3, 5.4, 7.2.3, 8.2.5, 9.2.0, 10.2.1, 10.2.2, 10.2.3, 11.2.1, 12.3.1, 12.4.1, 12.5.1 e), Annex C Fig. C3, 14, 4.6.3, 4.12); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-4:2018; EN 60598-2-13:2006 + A1:2012 + A2:2016 (Accepted clauses: 13.5, 13.6.4, 13.6.5, 13.7, 13.8, 13.9, 13.10, 13.11, 13.12, 13.14, 13.15); EN 62031:2008 + A1:2013 + A2:2015 (Accepted clauses: 7.3, 8, 9, 10, 12, 13, 16, 17 ); EN IEC 62031:2020 (Accepted clauses: 7.3, 8, 9, 10, 12, 13, 16, 17 ) 2020-09-25 2021-09-23 IMQ-379/E-CTF2-A
E-CTF 2 VIMAR S.p.A. [Prod. Cat.: INST - PROT] Via IV Novembre, 32 IT-36063 Marostica Vicenza (VI) Italy [INST] EN 61242:1997 + A1:2008 + A2:2016 + A13:2017 (All clauses except 25.2); EN 60669-1:1999 + A1:2002 + A2:2008 (All clauses except 24.2); EN 60669-1:2018 (All clauses except 24.2); EN 60669-2-1:2004 + A1:2009 + A12:2010 (All clauses except 24.2, 26); EN 60669-2-5:2016 (All clauses except 24.2, 26); EN 60670-1:2005 + A1:2013 (All clauses except 19); EN 60670-22:2006; EN 60670-24:2013 [PROT] EN 60898-1:2003 + A1:2004 + A11:2005 + A12:2008 + A13:2012 2005-12-05 2021-05-26 IMQ-084/CTF2-E
E-CTF 2 VORTICE ELETTROSOCIALI S.p.A. (Laboratorio prove R&D) Strada Cerca, 2 IT-20067 Tribiano Milano (MI) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.48); EN 60335-1:2012 + A11:2014 + A13:2017 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.48); EN 60335-2-30:2009 + A11:2012; EN 60335-2-80:2003 + A1:2004 + A2:2009 2007-06-28 2021-02-01 IMQ-114/CTF2-E
E-CTF 2 ZOBELE HOLDING S.p.A. (Electrical Testing Laboratory) Via Fersina, 4 IT-38123 Trento Trento (TN) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.32, 25.14, 27.5); EN 60335-2-101:2002 + A1:2008 + A2:2014 2006-10-17 2020-11-16 IMQ-100/CTF2-E
E-CTF 3 CANDY HOOVER GROUP S.r.l. (Cooking & Built-in Lab) Via Comolli, 16 IT-20861 Brugherio Monza-Brianza (MB) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, from 19.11.4.1 to 19.11.4.7); EN 60335-2-6:2015 + A1:2020 + A11:2020 (All clauses except 22.110, 22.111, 22.135, 22.136, 22.137, 32.101); EN 60335-2-102:2016 (All clauses except 8.101) 2021-12-01 0000-00-00 IMQ-403/E-CTF3 Issue No: 0
E-CTF 2 DE’ LONGHI APPLIANCES S.r.l. (Laboratorio MCM (Macchine Caffè Manuali)) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.48, Annex N, Annex R, Annex T); EN 60335-2-14:2006 + A1:2008 + A11:2012 + A12:2016; EN 60335-2-15:2016 + A11:2018 + A12:2021 + A1:2021 + A2:2021 2022-02-10 0000-00-00 IMQ-408/E-CTF2 Issue No: 0
Scheme Given name Family name Location Certification decision Signatory2 Scope limitation Terminated
ENEC+ Fulvio Giorgi Milano 2023-05-30 2023-05-30
ENEC, CCA, CCA/NTR, HAR Giorgio Belussi Milano 2017-01-01 2023-05-30
ENEC+ Giorgio Belussi Milano 2014-01-01 2023-05-30
ENEC, CCA, CCA/NTR, HAR Mauro Casari Milano 2008-01-01 2023-05-30
ENEC+ Mauro Casari Milano 2014-01-01 2023-05-30
HAR Marco Piazza Milano 2005-01-01 CABL 2023-05-30
CCA, ENEC Marco Piazza Milano 2005-01-01 LITE, SAFE 2023-05-30
CCA/NTR Marco Piazza Milano 2005-01-01 2023-05-30 CABLE, LITE, SAFE 2023-05-30
CCA, ENEC Fabrizio Stucchi Milano 2013-01-01 LITE, SAFE
CCA/NTR Fabrizio Stucchi Milano 2013-01-01 2023-05-30 LITE, SAFE
CCA, ENEC Massimiliano Rancati Milano 2016-01-01 LITE, SAFE
CCA/NTR Massimiliano Rancati Milano 2016-01-01 2023-05-30 LITE, SAFE
CCA, ENEC Augusto Ciciotti Milano 2005-01-01 INST, PROT, POW, MISC
CCA/NTR Augusto Ciciotti Milano 2005-01-01 2023-05-30 INST, PROT, POW, MISC
CCA, ENEC Fabio Taormina Milano 2017-01-01 INST, PROT, POW, MISC 2023-05-30
CCA/NTR Fabio Taormina Milano 2017-01-01 2023-05-30 INST, PROT, POW, MISC 2023-05-30
CCA, ENEC Armando Benvenuti Milano 2008-01-01 HOUS, TOOL 2023-05-30
CCA/NTR Armando Benvenuti Milano 2008-01-01 2023-05-30 HOUS, TOOL 2023-05-30
CCA, ENEC Stefano De Mas Milano 2014-01-01 CAP, HOUS, MEAS 2023-05-30
CCA/NTR Stefano De Mas Milano 2014-01-01 2023-05-30 CAP, HOUS, MEAS 2023-05-30
Given name Family name Location Registered date Terminated date
Giorgio Belussi Italy 2021-04-09
Luca Bergamo Italy 2021-04-09
Paolo Brambilla Italy 2021-04-09
Filippo Brivio Italy 2021-04-09
Bruno Brusaferri Brazil 2021-04-09
Andrea Capitanelli Italy 2021-04-09
Giuseppe Cassano Italy 2021-04-09
Fulvio Colombo Italy 2021-04-09
Massimo Di Dionisio Italy 2021-04-09
Diego Ferrari Italy 2021-04-09
Filippo Fiorentini Italy 2021-04-09
Antonio Forcina Italy 2021-04-09
Stefano Grilli Italy 2021-04-09
Paolo Magnani Italy 2021-04-09
Mario Marchelli Italy 2021-04-09
Roberto Mollo Italy 2021-04-09
Pasquale Pastocchi Italy 2021-04-09
Marco Piazza Italy 2021-04-09
Paolo Raffa Italy 2021-04-09
Livio Righetto Italy 2021-04-09
Giovanni Rodella Italy 2021-04-09
Davide Sanvito Italy 2021-04-09
Giuseppe Scuderini Italy 2021-04-09
Marco Tagliaferri Italy 2021-04-09
Claudio Veronese Italy 2021-04-09
Natalino Verzotto Italy 2021-04-09
Raffaele Villa Italy 2021-04-09
Berk Biricik Turkey 2021-04-09
Jorge López Spain 2021-04-09
Ming (Simeon) Chen China 2021-04-09
Yafeng (Ivan) Cheng China 2021-04-09
TiaoHui (William) Liu China 2021-04-09
Gabriele Panzeri China 2021-04-09
HongYun (Terry) Qiu China 2021-04-09
Aike (Echo) Yang China 2021-04-09
Mingjun (Stephen) Zhou China 2021-04-09